GGU-CANTILEVER: Reinforced concrete design
Reinforced concrete is designed to EC 2 or, alternatively, to DIN 1045 (old) depending on the selected safety factor concept. Reinforcement is calculated for all wall element sections (see “Theoretical principles: Structural system”). The output is the section with the largest reinforcement.
The stem area above the footing is designed using the wall internal forces (see “Theoretical principles: Cantilever wall-Determination of wall loads for reinforced concrete design“).
The internal forces M and Q at the stem base/toe and heel intersections are calculated from the soil pressure and any surcharge present. The model concept is a cantilever. The normal force N results from the passive earth pressure.
The following sign rule applies to the spur and wall moments with reinforcement: