Zum Hauptinhalt springen

GGU-RETAIN: "Verifications/Safety factors" menu item

If you are analysing with global safety factors to DIN 1054 old, you can specify the verifications to be performed by the program by activating the corresponding check boxes in the dialog box shown below.

Then enter the safety factors for the individual verifications. The program's default values in the box are those required by the EAB. For soldier pile walls, the safety factors for "Hydraulic heave" and "Buoyancy of base layer(s)" are removed. Then, the verification of "Sum H" can be activated instead. If you do not want the program to perform one of the verifications, the corresponding check box must be deactivated.