GGU-RETAIN: "Heave FOS summary" menu item
When analysing the system using global safety factors the base heave safety factor is determined automatically (see also “Theoretical principles: Base heave safety”). If this cannot be verified, you will see a corresponding warning even before analysis is complete. Otherwise, you can query the safety factor using this menu item.