GGU-STABILITY: "Verifications/Safety" menu item
With this menu item you can influence entries in the legend and in the print output table.

If, e.g., you do not wish to calculate bearing capacity with the simplified procedure, but would rather do an exact calculation using polygonal or circular slip surfaces, you may stop output of bearing capacity with the simplified procedure completely.
By pressing the "Default values" button the partial factors given in DIN 1054:2010 and EC 7 for the various load cases can be adopted (see menu item "Editor 1/Partial factors, …").